High efficient air cooled screw water chiller
Chillers are widely used in plastics, electronics manufacturing, electroplating, pharmaceutical and chemical, ultrasonic cooling, printing and other industrial productions. It can precisely control the temperature for modern industrial manufacturing and largely improve efficiency and product quality. It is the best choice for modern industries with simple operation, reasonable design and superior quality and over one hundred different models.
Advancement:
<Microcomputer control
(1). Adopt SIEMENS PLC which is with programmable touch panel controller.
(2). Monitoring the inlet/outlet chilled water temperature automatically. Through PLC control the slide valve automatically which will adjust the compressor load.
(3). Recording the alarm and the corresponding time automatically, and give the tips to handle the problem.
<superior performance
- . The main International advance semi-closed screw compressor in which electric motor and compressor are organically integrated to ensure no leakage of the shaft sealing;
- . Control programs for start and stoppage are applied to double or multiple compressors so as to balance the load and extend the service life of each component;
- . Several refrigeration circuits are provided for double or more compressors. When one circuits needs maintenance, other circuits can work properly as alternative circuits;
- . The compressor is started wit unloading and depression to avoid the impact to the power grid.
<Comprehensive security protection
- . Pressure protection: high pressure protection and low pressure protection;
- . Anti-freezing protection: the unit shall be stopped when the freezing water is too low;
- . Safe valve protection: when the refrigerant pressure exceeds the given valves, the safety relief valve will be automatically started.
- . All the aforementioned protection can ensure the unit a safe and stable operation.
<Low cost for operation and maintenance
- . The unit can be controlled by intelligent program in accordance with the needs of the load. 100%, 75%, 50%, 25%(start up), 0. By so doing, the energy can be saved;
- . The number of all components of screw compressor is 10% of load of the reciprocating compressor. The former is structurally simple, with fewer vulnerable components. Besides, it is not equipped with inlet and outlet valve and is of extremely low failure rate due to its low insensitivity to humidity itinerary;
- . The screw compressor can run for 40,000hours without any failure.
<Easy installation
- . The unit is so structurally compact that is only covers a little floorage to save the space of the machine room.
- . Before the unit leaving the factory, HAYE has tested the chiller to make sure the chiller without problem.
- . As for the air cooled chiller, customer only need to connect the chilled water pipe and no cooling tower needed.
Model[HYS-**A(H)S3] |
160 |
200 |
240 |
310 |
360 |
400 |
480 |
510 |
550 |
620 |
||
Cooling Capacity |
kW |
161 |
198 |
241 |
311 |
359 |
396 |
481 |
509 |
551 |
621 |
|
×104 kcal/h |
13.9 |
17 |
20.7 |
26.7 |
30.9 |
34.1 |
41.4 |
43.7 |
47.4 |
53.4 |
||
Total Refrigeration Input power(kW) |
54.5 |
62.8 |
80 |
99.9 |
115.1 |
125.6 |
160 |
160.8 |
184.5 |
199.8 |
||
Compressor |
Type |
Twin-screw semi-hermetic compressor advanced in the world |
||||||||||
Quantity |
unit |
1 |
1 |
1 |
1 |
2 |
2 |
2 |
2 |
2 |
2 |
|
Refrigeration Input power |
kW |
47.7 |
58.2 |
71.1 |
91.1 |
105.9 |
116.4 |
142.2 |
149.3 |
162.2 |
182.2 |
|
Heat Input power |
kW |
47 |
58 |
71 |
91 |
105 |
116 |
141 |
149 |
162 |
182 |
|
Energy Adjustment Step for Per Module |
25(start-up)-50-75-100% |
|||||||||||
Refrigerant |
Species |
—— |
R22 |
|||||||||
Control |
—— |
Thermal expansion valve External Balanced |
||||||||||
Fans |
Quantity |
unit |
4 |
4 |
4 |
6 |
8 |
8 |
8 |
10 |
10 |
12 |
Motor power |
kW |
1.1 |
1.4 |
1.46 |
1.47 |
1.1 |
1.4 |
1.46 |
1.47 |
1.47 |
1.47 |
|
Air Side Heat Exchanger |
Type |
Copper and aluminumfoil finned |
||||||||||
Water Side Heat Exchanger |
Type |
Dry shell and tube high efficiency evaporator |
||||||||||
Water Pipe Connection |
mm |
DN65 |
DN80 |
DN80 |
DN150 |
|||||||
Water flow |
m3/h |
28 |
34 |
41 |
53 |
62 |
68 |
83 |
87 |
94 |
106 |
|
Water Pressure Drop |
kPa |
48 |
52 |
55 |
55 |
44 |
44 |
48 |
48 |
52 |
55 |
|
Safe Protection Device |
High&Low pressure protection, anti-freezing and anti-heating protection, safety valve, overload protection, incomplete phase protection, opposite phase protection, lacking voltage and over voltage protection, water flow protection, etc |
|||||||||||
Dimensions |
Long |
mm |
2050 |
2410 |
2850 |
3550 |
4455 |
4815 |
5695 |
5950 |
6395 |
7095 |
Wide |
mm |
2100 |
2100 |
2100 |
2100 |
2100 |
2100 |
2100 |
2100 |
2100 |
2100 |
|
High |
mm |
2253 |
2253 |
2253 |
2253 |
2293 |
2293 |
2293 |
2293 |
2293 |
2293 |
|
Noise Value |
db(A) |
71 |
71 |
71 |
71 |
75 |
76 |
76 |
77 |
77 |
77 |
|
Total Weight |
kg |
1900 |
2090 |
2660 |
3160 |
3990 |
4180 |
5320 |
5250 |
5820 |
6320 |
|
Running Weight |
kg |
2000 |
2240 |
2810 |
3310 |
4215 |
4405 |
5545 |
5475 |
6045 |
6545 |
|
|
1、The refrigeration conditions for the above table: cold water inlet temperature is 12℃, the outlet temperature is 7℃ , and the ambient temperature is 35℃ |
|||||||||||
|
2. Power standard: 3N-380V-50Hz; Allow voltage fluctuation ± 10%, allowing phase voltage difference ± 2%; |
|||||||||||
|
3. Noise analysis from the host location for the front of 2m, 1.5m high office, before and after the four-point average of left and right; |
|||||||||||
Notes:Dimensions for reference only, actual size drawings shall prevail. |